10,018 research outputs found

    The role of inhibitory G proteins and regulators of G protein signaling in the in vivo control of heart rate and predisposition to cardiac arrhythmias

    Get PDF
    Inhibitory heterotrimeric G proteins and the control of heart rate. The activation of cell signaling pathways involving inhibitory heterotrimeric G proteins acts to slow the heart rate via modulation of ion channels. A large number of Regulators of G protein signalings (RGSs) can act as GTPase accelerating proteins to inhibitory G proteins and thus it is important to understand the network of RGS\G-protein interaction. We will review our recent findings on in vivo heart rate control in mice with global genetic deletion of various inhibitory G protein alpha subunits. We will discuss potential central and peripheral contributions to the phenotype and the controversies in the literature

    The cost of trauma operating theatre inefficiency.

    Get PDF
    The National Health Service (NHS) is currently facing a financial crisis with a projected deficit of £2billion by the end of financial year 2015/16. As operating rooms (OR) are one of the costliest components in secondary care, improving theatre efficiency should be at the forefront of efforts to improve health service efficiency. The objectives of this study were to characterize the causes of trauma OR delays and to estimate the cost of this inefficiency. A 1-month prospective single-centre study in St. Marys Hospital. Turnaround time (TT) was used as the surrogate parameter to measure theatre efficiency. Factors including patient age, ASA score and presence of surgical and anaesthetic consultant were evaluated to identify positive or negative associations with theatre delays. Inefficiency cost was calculated by multiplying the time wasted with staff capacity costs and opportunity costs, found to be £24.77/minute. The commonest causes for increased TT were delays in sending for patients (50%) and problems with patient transport to the OR (31%). 461 min of delay was observed in 12 days, equivalent to loss of £951.58/theatre/day. Non-statistically significant trends were seen between length of delays and advancing patient age, ASA score and absence of either a senior clinician or an anaesthetic consultant. Interestingly, the trend was not as strong for absence of an anaesthetic consultant. This study found delays in operating TT to represent a sizable cost, with potential efficiency savings based on TT of £347,327/theatre/year. Further study of a larger sample is warranted to better evaluate the identified trends

    A holistic approach to the evaluation of sustainable housing

    Full text link
    Residential housing is often evaluated against single or at best a limited number of similar criteria. These include quantifiable indicators such as energy use and its associated greenhouse gas emissions. It might also include material consumption from an embodied energy or resource use perspective. Social factors or qualitative indicators may be evaluated but are rarely placed or juxtaposed alongside these quantifiable indicators. A one-dimensional approach will be limiting because sustainable development includes both environmental and social factors. This paper describes the methodologies that have been developed to assess housing developments against five quite different criteria. These are: energy use, resource use, neighbourhood character, neighbourhood connectedness and diversity. In each case, high and low sustainability practice has been identified so that ranking is possible. These methodologies have then been tested by evaluating a typical precinct (approximately 400 m by 400 m) of a 1970-80s housing development in a suburb of Geelong. The rankings of the particular precinct have then been combined in a visual way to assist in the evaluation of the housing in a more holistic way. The results of this evaluation method are presented, along with a discussion of the strengths and weaknesses of the methodologies. The research is the outcome of collaboration by a cross-disciplinary group of academics within Deakin’s School of Architecture and Building

    The impact of national culture on the standardization versus adaptation of knowledge management

    Get PDF
    This paper examines the affect of national culture on knowledge management for multinational companies (MNCs). MNCs often have to decide whether to standardise or adapt their operations. Previous research has found that national culture has an effect in a range of MNC operations, e.g. human resources, marketing. However, there has been limited research on the influence of culture on knowledge management. We combine these perspectives to develop a conceptual framework that explores the decision to standardise or adapt knowledge management practices based on differences in national culture. The study extends current theoretical perspectives on knowledge management by exploring the cultural conditions that may lead to an adaptation decision, and whether there is a relationship between factors affecting a firm’s decision to standardise or adapt and the outcomes of knowledge management

    Analyticity and the NcN_c counting rule of SS matrix poles

    Full text link
    By studying ππ\pi\pi scattering amplitudes in the large NcN_c limit, we clarify the NcN_c dependence of the SS matrix pole position. It is demonstrated that analyticity and the NcN_c counting rule exclude the existence of SS matrix poles with M,ΓO(1){\cal M}, \Gamma\sim O(1). Especially the properties of σ\sigma and f0(980)f_0(980) with respect to the 1/Nc1/N_c expansion are discussed. We point out that in general tetra-quark resonances do not exist.Comment: This paper replaces hep-ph/0412175. The latter is withdraw

    An update of the JPL program to develop Li-SOCl2 cells

    Get PDF
    The goal of producing spiral wound D cell was met. The cell design and electrodes, particularly the carbon cathodes were produced in-house. Also all parts were assembled, the welding performed, the electrolyte aided and the cells sealed in-house. The lithium capacity (theoretical) was 19.3 Ah and that of the SOCl2 in the 1.8 m LiAlCl4 electrolyte, 16.4 Ah (a greater excess of SOCl2 is necessary for safe high rate operation). The electrode surface area was 452 sq cm. The carbon electrode comprised Shawinigen Black/Teflon -30 (90/10 by weight) mixture 0.020 inches thick on an expanded metal screen prepared in the JPL laboratory. There were two tab connections to the cathode. The 0.0078 inch thick lithium foil was rolled into an expanded nickel screen. The separator was Mead 934-5 fiberglass material
    corecore